PrinCE 560

 

The PrinCE 560 is one of the most flexible capillary electrophoresis systems. Both these systems are added with a second lift. This second lift is used to allow the change of outlet buffers at will.

 

Because of the dual lift approach, the PrinCE 550 and 560 is the most versatile of all CE instruments without external pressure possibilities. It is ideally suited for method development and routine analysis by one or more methods after another. The PrinCE 560 offers the possibility of sample and buffer cooling. Further the injection can be performed from short end. This reduces the effective capillary length. If the detector is used with a remote detector cell that fits into the oven compartment of the PrinCE, the capillary length can be reduced considerably.

 

Both PrinCE systems are fully automated and can handle up to 32 (or optional 40) samples without interference of the operator, while still maintaining 10 (or optional 5) buffer vials. Any combination of six segments (sample/buffer type) can be used. The operator can exchange the segments easily without needing any tools.

 

Under precisely controlled circumstances it is possible to use the PrinCE 550 and 560 for fraction collection.

 

The detector will typically be placed on top of the PrinCE, which will reduce bench space.

 

The extra features of PrinCE 560

 

  • Samples and Buffers cooling

 

Main Specifications:

 

 

 

      -  Flushing pressure

0 to +3000 mbar by DCI

      -  Voltage range

-30 kV to +30 kV

      -  Current range

-200 μA to + 200 μA

      -  Ramping

Programmable voltage or current ramping

      -  Polarity reversal

Programmable pre-run and during the run

      -  Autosampler

30/48 position carousel sample and buffer vials. Variable vial sizes for samples and buffers available, including Eppendorf micro centrifuge tubes

      -  Temperature control

Capillary 5°C below ambient to 60°C (PrinCE 550 and 560)
Samples and buffers: 4°C to 40°C (PrinCE 560)

      -  Detector

Allows the use of any CE-detector including MS, Fluorescence, Conductivity, UV/VIS, and Photo Diode Array

      -  Software

Allows the use of any data station. Optional: Our DAx Data Acquisition and Analysis software. This software is specially made for our PrinCE systems

 

 

 

Injection modes Hydrodynamic injection uses patended Dynamic Compression Injection (DCI) to generate and apply a range of positive and negative pressures with controlled ramping (-180 to 250 mbar, 1 mbar resolution). Electrokinetic Injection features controlled ramping in voltage or current mode (max. 30 kV).

 

8060_P4_0003.jpg

W ramach jednolitego systemu przechowywania/udostępniania elektronicznych wyników pomiarów z laboratoriów wydziałowych istnieje możliwość pobierania danych pomiarowych z Laboratorium Spektrometrii Mas. Dostęp do plików możliwy jest głównie poprzez protokół ftp (w tym bezpieczny wariant wykorzystujący szyfrowane połączenie z wykorzystaniem mechanizmu TSL/SSL: połączenia typu ftps lub ftpes):

  • serwer: labs.chem.uni.wroc.pl
  • użytkownik: Ten adres pocztowy jest chroniony przed spamowaniem. Aby go zobaczyć, konieczne jest włączenie w przeglądarce obsługi JavaScript.
  • hasło: identyczne jak do poczty wydziałowej

Dane pomiarowe można także pobierać korzystając z serwera FTP. Jest to zalecany i preferowany sposób odbioru widm, zwłaszcza jeśli ktoś często zleca wykonanie większej ilości pomiarów. Aktualne adresy IP, wraz z numerami portów, służące do połączeń FTP:

  • Shimadzu IT-TOF: 192.168.0.140:50008
  • Shimadzu qTOF: 192.168.0.141:50013

Warunkiem skorzystania z tej możliwości jest posiadanie konta na serwerze (osobne konto dla każdego z aparatów). Osoby zainteresowane prosimy o kontakt z dr Markiem Cebratem (tel. 7-151, pok. 253B).